SanDisk Industrial Grade CompactFlash 5000 Product Manual
© 2007 SanDisk® Corporation 29 July 2007
card configuration register addresses. All other attribute memory
locations are reserved.
Decoding for the configuration registers is defined in Table 24: Configuration
Registers Decoding..
Table 24: Configuration Registers Decoding
-CE2
X
-CE1
0
-REG
0
-OE 0 -WE 1 A10 0 A9 1
A8A4
00
A3
0
A2
0
A1
0
A0
0
Selected Register
Configuration Option
Read
X 0 0 1 0 0 1 00 0 0 0 0 Configuration Option
Write
X 0 0 0 1 0 1 00 0 0 1 0 Card Status Read
X 0 0 1 0 0 1 00 0 0 1 0 Card Status Write
X 0 0 0 1 0 1 00 0 1 0 0
Pin Replacement
Read
X 0 0 1 0 0 1 00 0 1 0 0
Pin Replacement
Write
X 0 0 0 1 0 1 00 0 1 1 0
Socket and Copy
Read
X 0 0 1 0 0 1 00 0 1 1 0
Socket and Copy
Write
3.4.1
Attribute Memory Function
The CompactFlash Memory Card identification and configuration information is
stored in the Attribute Memory, which is limited to 8-bit wide accesses only at
even addresses. The card configuration registers are also located in the
Attribute Memory.
For the Attribute Memory Read function, signals -REG and -OE must be active
and -WE inactive during the cycle. As in the Main Memory Read functions, the
signals -CE1 and -CE2 control the even-byte and odd-byte addresses, but only
the even-byte data is valid during Attribute Memory access. Refer to
Zobrazit stránku 35